A, the equipment use:
This equipment is used in vacuum or inert gas protection alloy material for high temperature heating under the environment of high temperature elevating the experimental furnace.
Second, the equipment technical parameters:
1. The highest temperature: 2300 ℃.
2. Use for a long time: 2100 ℃.
3. The heating rate: 30 / min.
Table 4. The temperature control precision: plus or minus 2 ℃.
5. The vacuum pressure rate (leak rate) : 15 Pa/h or less.
6. Temperature measurement accuracy, low temperature stage adopted thermocouple temperature measurement, the precision of + / - 5 ℃, high temperature stage USES far infrared temperature measurement, precision of plus or minus 30 ℃.
7. The high temperature heating zone active furnace size: 70 * 200 mm, and wall thickness of about 8 mm.
8. Boat material size: phi 30 (inner diameter) * 10 mm (height), wall thickness of about 5 mm.
9. The temperature control mode: intelligent temperature control instrument automatic temperature control.
10. Heating mode: by medium frequency induction heating, high precipitation absorption area using resistance heating.
11. The design of power: 18 kW.
12. The ultimate vacuum: 6.7 x 10-2.
Three, the structure of the equipment:
This equipment is mainly composed of lower the high temperature of induction heating area, indirect water cooling cooling in the middle of the transition area, precipitation in the upper absorption area such as the main structure, set up in the high temperature a platform at the bottom of the induction heating area, furnace bottom platform and operation platform, and vacuum system and electric control system components.