A, the equipment use:
Equipment is mainly used for calcining heat treatment of battery powder materials.
Second, the main technical parameters:
1, the chamber of a stove or furnace size: 17000 * 340 * 200 mm (L * W * H).
2, the highest temperature: 900 ℃.
3, mesh belt width: 315 mm.
4, run speed: 300-900 - mm/h continuously adjustable.
5, the number of sets of temperature control: temperature range of 11, 11 PM temperature control.
6, heating mode: the resistance heating wire and level.
Three, characteristics of the equipment:
Gas circuit configuration of mass flowmeter control with communication interface.
Discharge using correlation detection photoelectric switch.
Equipped with ultrasonic cleaning machine, zirconia oxygen analyzer.
Overall configuration computer monitor, collect and record temperature, oxygen concentration, transmission speed, gas flow, alarm information and other data. Through the computer interface can be easily set temperature curve, the key data transfer rate, etc. Software is equipped with the parameter change permissions (the administrator password modification, set parameters). Set aside three thermocouple access port is used to measure the temperature of the furnace left, middle and right three points, temperature curve can be displayed on the computer at the same time and record. Mesh belt speed regulation of electrical machine adopts stepless frequency converter speed control.


Note: according to user requirements design and manufacture.